24 V (ac) Transformer 009
009_D
05/14
Accessories
Replaces: 02/13
Installation & Operation Manual
1 of 2 © 2014 009_D - 05/14
Mount the Electrical Box
Mount the electrical box securely in the location where the transformer is to be installed.
Mount the transformer to the electrical box. Figure 1 shows how the transformer could be
mounted.
Basic Installation
The tekmar Transformer 009 is a 40 VA, 24 V (ac) transformer for use with products that require an external transformer.
The Transformer Kit 009K includes a 4" x 4" electrical J-Box.
Figure 1
When sizing a transformer it is important to know the load that it will be operating. Transformers are sized based on the VA
(Volt X Amps) power that they can provide. Use the sizing chart below to calculate the required VA. The tekmar Transformer
009 can supply a total of 40 VA. If the load exceeds 40 VA, a larger transformer is required.
Sizing the Transformer Load
Zone
123456
Thermostat
Load
Zone Valve
Load
Other Load
Control
Load (VA)
Total Zone Load
++++++
Transformer
must exceed:
VA
The high voltage side of the transformer can be determined by locating the two permanently connected, black and
black or black and white wires, which are factory-installed.
Connect 120 V (ac) hot (L) to the black (L) wire on the transformer.
Connect 120 V (ac) neutral (N) to the white or opposite black (N) wire on the transformer.
Low Voltage Side:
The low voltage terminals have male spade connectors and are labelled R and C.
Connect the red lead (with the in-line fuse) provided with the Transformer 009 to the R spade connector on the secondary
side of the transformer. The fuse is rated at 250 V (ac) 2.0 A slow-blow type.
Connect the black lead provided with the 009 to the C spade connector on the secondary side of the transformer.
To avoid serious personal injury and damage to the equipment:
It is your responsibility to ensure that this product is safely installed according to all applicable codes and
standards. tekmar is not responsible for damages resulting from improper installation and/or maintenance.
Read Manual and all product labels BEFORE using the equipment. Do not use unless you know the safe
and proper operation of this equipment.
It is the installers responsibility to ensure that this product is safely installed according to all applicable codes
and standards.
Ensure power to the circuit is off before wiring.
Wiring the Transformer
High Voltage Side: