Tekmar 162 Setpoint Control Installation User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
© 2007 D 162 - 08/07 2 of 32
Table of Contents
DIP Switches
Table of Contents ............................................................2
Display and DIP Switches ..............................................2
Dip Switches ...........................................................2
Access Levels .........................................................3
Display and Symbol Description .............................3
User Interface .........................................................4
Application Overview ......................................................5
On / Off Differential .................................................5
Pulse Width Modulation ..........................................6
Display Menus ................................................................7
VIEW Menu ............................................................7
ADJUST Menu ........................................................9
TIME Menu ...........................................................15
SCENE Menu .......................................................16
SCHEDULE Menu ................................................ 17
MISCELLANEOUS Menu ....................................19
Sequence of Operation ................................................20
Mode 1 - On / Off Setpoint ....................................20
Mode 2 - Hot Tub ..................................................20
Mode 3 - DHW Tank .............................................21
Mode 4 - PWM Setpoint .......................................21
Mode 5 - Floor ......................................................22
Mode 6 - Pool .......................................................22
Cycle Length ................................................................23
Relay Minimum On and Off Time .................................23
Remote Enable / Disable ..............................................23
Sensor Input .................................................................24
Time Clock ...................................................................24
Setting the Schedule ....................................................24
Scenes ..........................................................................25
Away Hold ....................................................................26
Restore Factory Defaults ..............................................27
Temperature Units ........................................................26
Backlight ......................................................................26
tN4 Features ................................................................26
Error Messages ............................................................29
Cleaning the Control ....................................................32
Warranty .......................................................................32
Display and DIP Switches
Lock / Unlock (DIP Switch #1)
Use the Lock / Unlock DIP switch to lock or unlock the
Access Level of the 162.
To unlock the Access Level, set the DIP switch to the
unlocked (left) position.
To lock the Access Level, set the DIP switch to the locked
(right) position. Once locked, a padlock is displayed in
the lower right corner of the display and the Access
Level cannot be changed.
Note: The tN4 System Control’s Lock / Unlock DIP switch
overrides the Lock / Unlock DIP switch on the 162. Set
the tN4 System Control’s Lock / Unlock DIP switch to the
Unlock position before Access Levels can be changed on
the setpoint control.
24 V ±10% 50/60 Hz 2.2 VA
24 V (ac) 2 A
Power:
Relays:
tN4 Setpoint Control 162
One Stage Heat / Cool
Feb 2006
Lot 1948
Meets Class B:
Canadian ICES
FCC Part 15
Cut jumper to
isolate relay
For product instructions see brochure
Use at least 194°F (90°C) conductors
/
24 V ±10% 50/60 H
24 V (ac) 2 A
Power:
Relays:
/
tN4 System Control (DIP Switch #2)
A tN4 System Control is a control, not a thermostat, that
the Setpoint Control 162 connects to through the tN4
bus. All tN4 compatible Outdoor Reset Modules are tN4
System Controls.
If the thermostat is connected to a tN4 System Control,
set the tN4 System Control DIP switch to tN4 System
Control (left position).
If the thermostat is not connected to a tN4 System
Control, set the tN4 System Control DIP switch to None
(right position).